SEISCO...The Tankless Water Heater

That Others Can Only Claim To Be!

Return to Main Page


Any QuestionsE-Mail Me


Robert Rolleston

2664 County Route 17

Granville, NY 12832

Phone: 518-260-5934

Fax: 518-824-1217

Email: RRolleston@electrictankless.com



Click Here for prices and to order


In 1995 DuPont joined David Seitz, the developer of the SEISCO, in his efforts to develop a complete new level of technology for tankless water heaters for any application. Now after over 14 years of research and testing, the SEISCO, whose technology has earned its developer 5 separate U.S. and many additional foreign patents, is recognized as the STANDARD for all tankless water heaters.

The SEISCO tankless water heater has earned International recognition. for providing the highest level of temperature control performance, reliability and safety in its operation over any tankless water heater anywhere in the world today.

There are many application's a SEISCO tankless water heater can be used such as specialty restaurants, convenience stores, hotels, pet grooming shops. A perfect back-up to Solar and Geothermal passive heat recovery systems and a powerful replacement for boilers and storage tanks used in Hydronic heating and Radiant Floor heating systems. For radiant/hydronic heating SH units are required.

Below are the heater Specifications, Details, Temperature rise with flow rate charts. Please contact me so I can help you chose a unit that will best suite your needs. Model numbers 7 and 5 are not shown on the product specification table below. They are mostly for low usage areas in warm climates or small radiant heating applications or warm water hand wash sinks.



Specifications

Two element Models

Four element models

Dimensions:

15¾×10¼×6¼ in

15¾x15¾x6¼ in.

Weight:

15.00 Lb.

23.00 Lb.

Pipe Fittings:

3/4" Standard Pipe NPT

3/4" Standard Pipe NPT

Voltage:

240Volts

240Volts

Amps:

21-58

75-116

Kw:

5-14

18-28

Breakers Required:

2 Double pole breakers

4 Double pole breakers

Wire size

Check local codes

Check local codes

Hz:

50/60

50/60

Min GPM:

N/A

N/A

Min/Max PSI:

0/125

0/125

RA Min/Max Temp:

85/130

85/130

SH Min/Max Temp:

95/150

95/150

Heat Output (BTU)

17,060-47780

61430-95560

Energy Efficiency:

99.5%

99.5%

Warranty:

10 year limited/ 3 years: materials and workmanship on chamber & control board/ 1 year: heating elements

10 year limited/ 3 years: materials and workmanship on chamber & control board/ 1 year: heating elements

Certifications:

UL

UL


General Product Description

RADIANT HEATING:  Radiant heating [SH] models are also available.  Please contact me for info.  The specifications on the SH models are the same as the RA models.

 

SIZE:  Seisco Water Heaters are manufactured in two basic sizes, a large four-chamber unit and a smaller two-chamber unit The same advanced microprocessor technology and thermoplastic construction are used in both sizes. Therefore, many of the parts are interchangeable.

MODELS:
  There are four models of the four-chamber models.  They are RA-18, RA-22, RA-28, & RA-32. These models are designed generally for domestic water heating in whole house and booster applications. Also, there are five two-chamber models.  They are RA5,RA7,RA-9, RA-11, & RA-14. The two-chamber models are designed for small space heating applications and point-of-use in commercial applications. The available models and their descriptions are listed on pages following this section.

FEATURES:  There are no moving parts or flow restricting devices used in Seisco heaters. Seisco uses a unique flow/no flow detection system utilizing it’s temperature sensors for flow detection. In standby, the heater maintains a very subtle temperature gradient and flow is detected when there is a change in the gradient. The advanced microprocessor control turns the power on through a set of relays and turns the power off when flow stops. The most important feature may be the patented “Power Sharing” technology which provides for evenly distributed power to the heating elements. This in turn, helps eliminate scalding potential, scaling and sediment build-up. Also, the control logic allows the power level to vary which is beneficial in minimizing the use of power for periods of less demanding usage. 

CONSTRUCTION:  Seisco heating chambers are modular and molded of light weight thermoplastic materials. The chamber is specifically engineered for durability in harsh water heating environments and capable of withstanding extreme temperature swings and pressure changes. Heating elements, sensors and detection devices, that come in contact with the water, are machined in brass or made of copper to help resist corrosion. Standard 1 ½ inch, flanged screw-type heating elements are utilized which are interchangeable with heating elements available at local hardware stores.

SAFETY AND MAINTENANCE:  Seisco was designed with a complete array of dependable safety features to prevent harm to the user and the heater. There are several redundant safety features as well. They include, dual high temperature switches on independent circuitry in addition to the control’s internal high temperature shut down. Dual low level detectors are used to prevent dry firing of the heating elements and a leak detector is mounted on the casing that in the event of a leak, sounds an alarm to the user. Although the control board is protected against electrical surges, additional heater protection is achieved when the relays are opened during periods of standby, providing no path for the surge to reach the heating elements. Also, the chamber is designed with a patented venting system that continuously vents harmful gasses and air during operation.  The microprocessor control is programmed to provide self diagnostics that significantly reduces trouble shooting and service time. In the event of a problem with the heater, the control emits a visual or optional built-in audible code. There is no maintenance required of the Seisco. However, there are clean-out plates below the heater chamber to allow removal of sand and grit that may build-up from a well water system.

POWER RATING:  The four-chamber models contain four electric heating elements whose combined wattage is the total power rating of the heater. For instance, the standard RA-28 model contains four 7000 watt elements for a total of 28,000 watts, or 28 kilowatts (kW) of power. The two-chamber model, RA-14, contains only two 7000 watt elements for a total power rating of 14,000 watts, or 14 kilowatts (kW). However, because of Seisco’s “Power Sharing” technology, the heater may not always use the maximum available power. The power output can vary with flow rate and temperature rise. Refer to the Product Specifications Table for the maximum power ratings of each model. 

HEATING OUTPUT:   The heating output of the Seisco is simply the total kilowatt power rating of the combined heating elements converted to BTU’s using 3,413 BTU/kW. For instance, the RA-28 has a total power rating of 28 kW or a 95,564 BTU heat output rating. The four-chamber models have the higher output ratings; 61,434 BTU’s for the RA-18 model, and 75,086 BTU’s for the RA-22 model. The lower output two-chamber models, are; 47,782 BTU’s for the RA-14, 37,543 BTU’s for the RA-11, and 30,717 BTU’s for the RA-9. These ratings vary with the operating voltage or service voltage to the heater. Refer to the Product Specifications Table for the BTU ratings of each model.

VOLTAGE RATING:  Seisco heaters are manufactured with common 240 volt (AC) heating elements designed for optimum operation on a standard residential 240 volt (AC) electric service. Also, the Seisco will operate at 208 VAC, a typical commercial voltage, with standard 240 VAC heating elements. However, when operating the heater at 208 VAC, the power rating and the heat output rating is significantly reduced. Seisco models can be special ordered with 208 VAC heating elements to help maximize the power and heating output. Refer to the Product Specifications Table for details on the various voltage ratings.

MAXIMUM CURRENT RATING:  Each Seisco Model has a maximum electrical current rating (or amp rating) equivalent to the sum of the heating element ratings. For example, a four-chamber model, RA-28, operating at 240 VAC has four heating elements, each with a maximum rating of 29 amps. The maximum current rating or total current rating of the RA-28 is therefore 116 amps or the sum of the four heating elements. However, because of Seisco’s “Power Modulating Technology”, the actual current measured during relatively low flow rates and/or low temperature rises can be less than the maximum rating of the heater during operation. Refer to the A (max) or maximum amp rating under “Electrical” in the Product Specifications Table for each model. 

TEMPERATURE RISE:  The temperature rise must be determined in order to help choose the appropriate Seisco heater. The rise can be determined by knowing the input water temperature and the desired output temperature of the heater. The Seisco’s output temperature is typically set for about 120 degrees F at the factory. Therefore, if the input or cold water inlet temperature is 50 degrees F, then the temperature rise is the difference or 70 degrees F. If the desired output temperature is 125 degrees F, then the temperature rise would be 75 degrees F. With the temperature rise determined, the Product Specification Table  provides the associated flow rate capacity of the various Seisco models.

FLOW RATE:  The flow rate for each model is given in the “Temperature Rise” table of the Product Specification Table.  Along with the temperature rise, the flow rate must also be determined in order to choose the appropriate Seisco heater. The flow rate is determined by the type of faucet and also, life style. Refer to the chart below for typical faucet flow rates in the home. However, if the desired life style in the home requires running multiple faucets at the same time, then the flow rates must be added together to determine the peak flow demand. The Seisco or the possibility of multiple Seisco’s should be selected to match the peak flow rate.


Product Specification Table

Standard 240 Volt (AC) Operation,  240 VAC Rating

SEISCO® Electric Fluid Heating System 

[ TWO Chamber Models ]


MODEL

RA-14

RA-11

RA-9

kW

14

11

9

Elements

7000 watts ´ 2

5500 watts ´ 2

4500 watts ´ 2

Btu/hr

47780

37540

30710

kg-cal/min

200

158

129

TEMPERATURE RISE

 

95 °F @ 1.0 GPM

64 °F @ 1.5 GPM

48 °F @ 2.0 GPM

38 °F @ 2.5 GPM

75 °F @ 1.0 GPM

50 °F @ 1.5 GPM

37 °F @ 2.0 GPM

30 °F @ 2.5 GPM

61 °F @ 1.0 GPM

40 °F @ 1.5 GPM

30 °F @ 2.0 GPM

24 °F @ 2.5 GPM


50 °C @    4 L/min

33 °C @   6 L/min

25 °C @   8 L/min

20 °C @ 10 L/min

39 °C @    4 L/min

26 °C @   6 L/min

20 °C @   8 L/min

16 °C @ 10 L/min

32 °C @    4 L/min

21 °C @   6 L/min

16 °C @   8 L/min

13 °C @ 10 L/min

MECHANICAL

Size H×W×D

15¾×10¼×6¼ in /

40×26×16 cm

15¾×10¼×6¼ in /

40×26×16 cm

15¾×10¼×6¼ in /

40×26×16 cm

Plumbing fittings

¾-in NPT nipple × 2

¾-in NPT nipple × 2

¾-in NPT nipple × 2

Shipping weight

15 lbs / 7 kg

15 lbs / 7 kg

15 lbs / 7 kg

ELECTRICAL

V

240

240

240

A (max)

58

46

37.5

Hz

50 / 60

50 / 60

50 / 60

Circuits[1]

30A × 2

50A × 1

40A × 1

APPLICATIONS

 

Whole-house unit;
for use where ambient water temperature rarely drops below 75 °F / 24 °C. Single shower / sink; hunting and fishing cabins; supplementing existing water heaters which are unable to satisfy users requirements. Radiant floor heating.

Point-of-use such as: coffee bars; wash sinks in light industrial warehouse; emergency showers; to comply with code; supplementing existing water heaters; RV’s and small motor homes; Radiant floor heating.

Point-of-use such as: coffee bars; wash sinks in light industrial warehouse; emergency showers; to comply with code; supplementing existing water heaters; RV’s and small motor homes; Radiant floor heating.

[1] Each circuit requires one double-pole breaker (240 V line to line connection).


Standard 240 Volt (AC) Operation,  240 VAC Rating

SEISCO® Electric Fluid Heating System

[ Four Chamber Models ]


MODEL

RA-28

RA-22

RA-18

kW

28

22

18

Elements

7000 watts ´ 4

5500 watts ´ 4

4500 watts ´ 4

Btu/hr

95560

75080

61430

kg-cal/min

400

315

258

TEMPERATURE RISE

 

95 °F @ 2.0 GPM

76 °F @ 2.5 GPM

64 °F @ 3.0 GPM

48 °F @ 4.0 GPM

75 °F @ 2.0 GPM

60 °F @ 2.5 GPM

50 °F @ 3.0 GPM

37 °F @ 4.0 GPM

61 °F @ 2.0 GPM

49 °F @ 2.5 GPM

40 °F @ 3.0 GPM

30 °F @ 4.0 GPM


50 °C @   8 L/min

40 °C @ 10 L/min

33 °C @ 12 L/min

25 °C @ 16 L/min

39 °C @   8 L/min

31 °C @ 10 L/min

26 °C @ 12 L/min

20 °C @ 16 L/min

32 °C @   8 L/min

26 °C @ 10 L/min

21 °C @ 12 L/min

16 °C @ 16 L/min

MECHANICAL

Size H×W×D

15¾×15¾×6¼ in /

40×40×16 cm

15¾×15¾×6¼ in /

40×40×16 cm

15¾×15¾×6¼ in /

40×40×16 cm

Plumbing fittings

¾-in NPT nipple × 2

¾-in NPT nipple × 2

¾-in NPT nipple × 2

Shipping weight

23 lbs / 10.5 kg

23 lbs / 10.5 kg

23 lbs / 10.5 kg

ELECTRICAL

V

240

240

240

A (max)

116

91

75

Hz

50 / 60

50 / 60

50 / 60

Circuits[2]

30A × 4

50A × 2

40A × 2

APPLICATIONS

 

Whole-house unit;
specialty restaurants; convenience stores; hotels; pet grooming establishments.
Backup to passive systems such as solar and heat-recovery.
Radiant floor heating. Minimum 200A electrical service.

Whole-house unit;
for use where ambient water temperature rarely drops below
55 °F / 13 °C.
Radiant floor heating.
Minimum 150A electrical service.

Whole-house unit; for use where ambient water temperature rarely drops below 65 °F / 18 °C.

Radiant floor heating. Minimum 125 recommended electrical service.

[2]   Each circuit requires one double-pole breaker (240 V line to line connection).